Fuji Prescale Pressure Measurement Film
Product Information
Product Range

Product Code

Pressure range [MPa] 1MPahttp://www.prescale.co.uk/prescale/products.html10.2kgf/cm2
Fuji Prescale Pressure Measurement Film Preassure Range
Pressure range [psi] 1psihttp://www.prescale.co.uk/prescale/products.html6895pa
Product Size
W(mm)×L(m)
Type
Fuji Prescale Pressure Measurement Film
Fuji Prescale Pressure Measurement Film
Fuji Prescale Pressure Measurement Film
Fuji Prescale Pressure Measurement Film
Fuji Prescale Pressure Measurement Film
Fuji Prescale Pressure Measurement Film
Fuji Prescale Pressure Measurement Film
Fuji Prescale Pressure Measurement Film
Super high pressure (HHS)
High pressure (HS)
Medium pressure (MS)
Medium pressure (MW)
Low pressure (LW)
Super low pressure (LLW)
Ultra super low pressure (LLLW)
Extreme low pressure (4LW)
 
 
 
 
 
 
 
 
270 × 12
270 × 12
270 × 12
270 × 12
270 × 12
270 × 6
270 × 5
270 × 3
Mono sheet
Mono sheet
Mono sheet
Two-sheet
Two-sheet
Two-sheet
Two-sheet
Two-sheet
Technology
Two-sheet type extreme low pressure, ultra super low pressure, super low pressure, low pressure, medium pressure (5 types)
Composed of two kinds of films: A-film and C-film
  • A-film: Base material (PET base) coated with a color-forming material (microcapsules)
  • C-film: Base material (PET base) coated with a color-developing material

The coated sides of each film (color-forming and color-developing) must face each other.These are the sides with the matt finish.When pressure is applied, the microcapsules are broken and the color-forming material transfers to the color-developing material and reacts, thereby generating a red color.

Fuji Prescale Pressure Measurement Film
Mono-sheet type medium pressure, high pressure, super high pressure (3 types)
Measurement is possible with a single sheet of film.
  • A color-developing material and color-forming material (microcapsules) are coated, one above the other, on a single base material (PET base).

When pressure is applied, the microcapsules are broken and the color-developping material absorbs the color-forming material and reacts, thereby generating a red color.

Fuji Prescale Pressure Measurement Film
Specification and Operational Environment
Prescale (Two-sheet type / Mono-sheet type)
Accuracy ±10% or less (when measured with densitometer at 23°C / 73.4°F, 65%RH)
Recommended temperature 20°C ~ 35°C (68°F ~ 95°F) Recommended humidity 35%RH ~ 80%RH
Thickness Mono-sheet : ca. 110µ   Two-sheet : A film : ca. 90µm, C film : ca. 90µm
*Each type of products have different thicknesses
Pressure Chart (Low Pressure (LW) case)
  • Continuous pressure
Measurement pressure range: Low pressure (2.5~10MPa) Pressure application condition: Time to reach the pressure 2min. Time of retention at the pressure 2min.
Fuji Prescale Pressure Measurement Film
  • Momentary pressure
Measurement pressure range: Low pressure (2.5~10MPa) Pressure application condition: Time to reach the pressure 5sec. Time of retention at the pressure 5sec.
Fuji Prescale Pressure Measurement Film